Power Systems
Switchgear And Paralleling Controls
Cat Customizable Switchgear and Controls
- Configuration
- Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
- Modes of Operation
- All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical power needs
- Application
- LV and MV ( 208V - 38 kV) 50 / 60 Hz
View Details
Cat EGP Switchgear
- Configuration
- Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
- Modes of Operation
- Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
- Application
- LV and MV (208V - 38 kV)
View Details
Cat Switchgear
- Configuration
- IP4X
- Operating Temperature
- 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
- Standard Widths
- 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
View Details
Cat XLM Switchgear
- Configuration
- Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
- Modes of Operation
- Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
- Application
- LV and MV ( 208V - 38 kV
View Details
EMCP 4.4 Master Control Panel
- Configuration
- Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.
- Modes of Operation
- Emergency standby, island, utility paralleling
- Application
- LV and MV (208V - 38 kV)
View Details
Engine Paralleling and Integration Control (EPIC)
- Configuration
- Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)
- Modes of Operation
- Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
- Application
- LV and MV (208V-27kV)
View Details